Single Phase Fully Controlled Bridge Rectifier with R, RL & RLE Load

Introduction

A Single Phase Fully Controlled Bridge Converter (Rectifier) is a power electronic circuit that converts single phase AC voltage into controlled DC voltage using four thyristors (SCRs) arranged in a bridge configuration. The output DC voltage can be varied smoothly by changing the firing angle (α) of the SCRs.

Single Phase Fully Controlled Bridge Rectifier with R Load

“Single phase fully controlled bridge converter with R load circuit diagram”
Fig. 1 :Circuit diagram of 1- phase fully controlled bridge Rectifier – R load

Operation

During Positive Half Cycle (α <ωt< π)
In the positive half cycle, thyristors T1 and T2 are forward biased and conduct when triggered at firing angle α. Current flows through T1 → R load → T2, producing a positive output voltage across the load. Since the load is resistive, current follows the voltage and becomes zero at the end of the half cycle.

During Negative Half Cycle (π+α <ωt< 2π)
In the negative half cycle, thyristors T3 and T4 are forward biased and conduct when triggered at angle α. Current flows through T3 → R load → T4 in the same direction as before, giving a unidirectional output. The current again becomes zero when the input voltage crosses zero.

Output Waveform

“Waveforms of single phase full wave bridge converter with R load”
Fig. 2 : Waveforms of Single Phase Full Wave Bridge Rectifier with R Load

Average Output Voltage

Vavg=2VmπcosαV_{avg} = \frac{2V_m}{\pi} \cos \alpha

Where:

  • VmV_m​ = Maximum value of AC input voltage
  • α\alpha = Firing angle

Average Output Current

Since load is resistive:Iavg=VavgR=2VmπRcosαI_{avg} = \frac{V_{avg}}{R} = \frac{2V_m}{\pi R} \cos \alpha

Where:

  • RR = Load resistance

RMS Output Voltage

Vrms=Vm12sin2α4πV_{rms} = V_m \sqrt{\frac{1}{2} – \frac{\sin 2\alpha}{4\pi}}

RMS Output Current

Irms=VrmsR=VmR12sin2α4πI_{rms} = \frac{V_{rms}}{R} = \frac{V_m}{R} \sqrt{\frac{1}{2} – \frac{\sin 2\alpha}{4\pi}}

Single Phase Fully Controlled Bridge Rectifier with RL Load

“Circuit diagram of single phase fully controlled bridge rectifier with RL load”
Fig. 3 : Single phase fully controlled bridge Rectifier with RL load

Operation

When the AC supply is applied, two thyristors conduct in each half cycle depending on the firing angle α. During the positive half cycle, thyristors T1 and T2 are forward biased and are triggered at ωt=α\omega t = \alpha. Current flows through T1 → R–L load → T2, producing a positive output voltage. Due to the presence of inductance, the load current does not become zero at ωt=π\omega t = \pi and continues beyond this point.

In the negative half cycle, thyristors T3 and T4 are triggered at ωt=π+α\omega t = \pi + \alpha. Current now flows through T3 → R–L load → T4 while maintaining the same direction in the load. Because of the inductive load, current overlaps between successive thyristor pairs, ensuring continuous current flow. By varying the firing angle α, the average output voltage and current can be controlled.

Mode Determination

  • Continuous Conduction Mode (CCM)

Occurs when the load inductance is sufficiently large:L>LcriticalL > L_{critical}

Discontinuous Conduction Mode (DCM)
Occurs when the load inductance is small:L<LcriticalL < L_{critical}

Output Waveform

“Waveforms of single phase fully controlled bridge converter with RL load”
fig. 4 :Waveforms of 1-phase fully controlled bridge Rectifier with RL load (Continuous)

Average Output Voltage

Vavg=2VmπcosαV_{avg} = \frac{2V_m}{\pi} \cos \alpha

Average Output Current

For RL load (with continuous current):Iavg=VavgR=2VmπRcosαI_{avg} = \frac{V_{avg}}{R} = \frac{2V_m}{\pi R} \cos \alpha

RMS Output Voltage

Vrms=Vm12sin2α4πV_{rms} = V_m \sqrt{\frac{1}{2} – \frac{\sin 2\alpha}{4\pi}}

RMS Output Current

Irms=VrmsR=VmR12sin2α4πI_{rms} = \frac{V_{rms}}{R} = \frac{V_m}{R} \sqrt{\frac{1}{2} – \frac{\sin 2\alpha}{4\pi}}

Single Phase Fully Controlled Bridge Rectifier with RLE Load

In an RLE load, the circuit consists of Resistance (R), Inductance (L), and a DC source (E) (such as a battery or back-emf of a motor).
The inductance maintains current continuity, while E may oppose or assist the supply, allowing both rectification and inversion.

single phase fully controlled rectifier with rle load

fig. 5:single phase fully controlled rectifier with rle load

Operation

Positive Half-Cycle (α <ωt< π)

  • Thyristors T1 and T2 are forward-biased.
  • They do not conduct until they receive a firing pulse at delay angle α.
  • Once triggered, the load voltage Vo follows the supply voltage Vs.
  • Energy Storage: The inductor L stores energy, which allows the current to continue flowing even after Vs drops below E or passes zero.

Negative Half Cycle (π < ωt < 2π)

  • AC supply voltage is negative.
  • Thyristors T3 and T4 are forward biased.
  • When triggered at π + α, T3 and T4 conduct.
  • Current path:
    Vs → T3 → R → L → E → T4 → Vs
  • Load current continues in the same direction.

Modes of Operation

1. Rectification Mode (α < 90°)

  • Average output voltage is positive.
  • Power flows from AC source to DC load.

2. Inversion Mode (α > 90° and E present)

  • Average output voltage becomes negative.
  • Power flows from DC side back to AC supply (regenerative operation).

Output Waveform

single phase fully controlled rectifier with rle load waveform
fig 6: waveform of 1-phase fully controlled rectifier- rle load